Only report core throttles per core, not per cpu (#836)
* Only report core throttles per core, not per cpu * Add topology/core_id to the cpu sysfs fixtures * Add new cpu fixtures to ttar file * Merge core_id reading and thermal throttle accounting * Declare core_id
This commit is contained in:
parent
79ae03c4c7
commit
c504c7e264
3 changed files with 53 additions and 9 deletions
|
|
@ -21,6 +21,7 @@ import (
|
|||
"os"
|
||||
"path/filepath"
|
||||
"regexp"
|
||||
"strconv"
|
||||
"strings"
|
||||
|
||||
"github.com/prometheus/client_golang/prometheus"
|
||||
|
|
@ -70,11 +71,10 @@ func NewCPUCollector() (Collector, error) {
|
|||
"Maximum cpu thread frequency in hertz.",
|
||||
[]string{"cpu"}, nil,
|
||||
),
|
||||
// FIXME: This should be a per core metric, not per cpu!
|
||||
cpuCoreThrottle: prometheus.NewDesc(
|
||||
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "core_throttles_total"),
|
||||
"Number of times this cpu core has been throttled.",
|
||||
[]string{"cpu"}, nil,
|
||||
[]string{"core"}, nil,
|
||||
),
|
||||
cpuPackageThrottle: prometheus.NewDesc(
|
||||
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "package_throttles_total"),
|
||||
|
|
@ -104,6 +104,8 @@ func (c *cpuCollector) updateCPUfreq(ch chan<- prometheus.Metric) error {
|
|||
|
||||
var value uint64
|
||||
|
||||
cpu_core_throttles := make(map[int]uint64)
|
||||
|
||||
// cpu loop
|
||||
for _, cpu := range cpus {
|
||||
_, cpuName := filepath.Split(cpu)
|
||||
|
|
@ -134,10 +136,21 @@ func (c *cpuCollector) updateCPUfreq(ch chan<- prometheus.Metric) error {
|
|||
log.Debugf("CPU %v is missing thermal_throttle", cpu)
|
||||
continue
|
||||
}
|
||||
if value, err = readUintFromFile(filepath.Join(cpu, "thermal_throttle", "core_throttle_count")); err != nil {
|
||||
return err
|
||||
|
||||
if value, err := readUintFromFile(filepath.Join(cpu, "topology/core_id")); err != nil {
|
||||
log.Debugf("CPU %v is misssing topology/core_id", cpu)
|
||||
} else {
|
||||
core_id := int(value)
|
||||
if value, err = readUintFromFile(filepath.Join(cpu, "thermal_throttle", "core_throttle_count")); err != nil {
|
||||
return err
|
||||
}
|
||||
cpu_core_throttles[core_id] = value
|
||||
}
|
||||
ch <- prometheus.MustNewConstMetric(c.cpuCoreThrottle, prometheus.CounterValue, float64(value), cpuNum)
|
||||
}
|
||||
|
||||
// core throttles
|
||||
for core_id, value := range cpu_core_throttles {
|
||||
ch <- prometheus.MustNewConstMetric(c.cpuCoreThrottle, prometheus.CounterValue, float64(value), strconv.Itoa(core_id))
|
||||
}
|
||||
|
||||
nodes, err := filepath.Glob(sysFilePath("bus/node/devices/node[0-9]*"))
|
||||
|
|
|
|||